Have you ever struggled with getting the temperature just right in your home?
Too Hot, Too Cold?

If that sounds familiar, well… chances are your Air Conditioning & Heating System was NOT sized Properly. 

In fact, most older A/C Systems are oversized, so just replacing a 10- to 15-year-old Heating & Air Conditioning System with a properly sized one can save you as much as 30-40% on your Energy bill!

That’s right! A little extra cash in your pocket and a whole lot of family comfort.

However, the only accurate method to perform air conditioning sizing in a particular home, is to calculate the actual heating or cooling load on the property. A calculation professionally referred to in the Construction Industry as a Manual J based load analysis.

Any Air Conditioning & Heating system not only consumes vast amounts of a home’s total energy budget, but also impacts the comfort and well-being of the occupants more than any other system in a house. Since A/C systems play such a large role in a home’s performance, it’s important that they receive enough “design” attention to make sure they’ll perform the best way possible.

Ready to get started?
Do you Need a Manual J Calculation for your Home?
Call us at 1-800-810-3280 or simply Click Here…

WHAT SPECIFIC INFORMATION WILL AN ACCA MANUAL J PROVIDE ABOUT MY HOME?

[subheader]Manual J Calculations Are Used To Determine The Amount Of Heat The House Loses In Winter And Gains In Summer.[/subheader]

Manual J: A/C Load Calculations may be done room-by-room for the whole house, which allows you to determine how much conditioned air, in cubic feet per minute CFM each room needs for both heating and cooling.

[one_half] It factors in all the surfaces of the building envelope, with their areas and insulation levels. Each wall is given its proper orientation, as well as the windows and doors attached to them.

Additional important data to include is the location and tightness of the duct system, the infiltration rate of the house, the internal loads (appliances and people), and area where the house is located.[/one_half]

[one_half]The results specify the BTUH of heat lost by each room in the winter and gained in the summer.

The heat gain is split into two parts:

[list type=”bullet”]

  • Sensible (related to temperature)
  • Latent (related to humidity).

[/list]

[/one_half]

[clear][clear]
[center][button url=”https://www.manualjcalculator.com/#manual-j-calculation-electronic-request-form” ]ONLINE REQUEST FORM[/button] [button url=”https://manualjcalculator.com/wp-content/uploads/2014/01/Sample-Manual-J.pdf” ]DOWNLOAD FULL MANUAL J SAMPLE[/button] [button url=”https://www.manualjcalculator.com/#manual-j-calculation” ]VIEW PRICING[/button][/center][clear]

AVOID OVER SIZED A/C SYSTEMS

[subheader]Get Your Home Air Conditioning Calculation Properly Done, Right From The Start![/subheader]

[one_half] ACCA developed its Manual J protocol for heating and cooling load calculations to help HVAC contractors put in correctly sized equipment, but there are a couple of problems:
[list type=”bullet”]

  • First: most contractors don’t do the load calculations for every new piece of equipment they install. They use rules of thumb instead.
  • Second: when they do the Manual J, they sometimes don’t do them correctly.

[/list]
We’ve looked over a lot of Manual J reports because the ENERGY STAR homes program actually requires them.
[/one_half]

[one_half]ENERGY STAR doesn’t require a whole lot. Mainly they want to check that the following info is correct:
[list type=”check”]

  • Location
  • Outdoor & Indoor design temperature
  • Orientation
  • Windows
  • Number of People
  • Ducts

[/list]
[/one_half]

[clear][clear]
[center][button url=”https://www.manualjcalculator.com/#manual-j-calculation-electronic-request-form” ]ONLINE REQUEST FORM[/button] [button url=”https://manualjcalculator.com/wp-content/uploads/2014/01/Sample-Manual-J.pdf” ]DOWNLOAD FULL MANUAL J SAMPLE[/button] [button url=”https://www.manualjcalculator.com/#manual-j-calculation” ]VIEW PRICING[/button][/center][clear]

IN SUMMARY

[subheader]Get a Manual J HVAC Load Calculation done by an HVAC professional[/subheader][clear]
[one_third]A typical Manual J report will provide you with important information regarding the heating & cooling requirements for each
floor of your home.[/one_third][one_third]A precise Manual J HVAC load calculation is the starting point to any Heating or Air Conditioning System installation or replacement. [/one_third][one_third]Regardless of what type of HVAC System you may need you should always start with a load calculation on your home to determine the right size for your equipment.[/one_third]
[clear][clear]
[center][button url=”https://www.manualjcalculator.com/#manual-j-calculation-electronic-request-form” ]ONLINE REQUEST FORM[/button] [button url=”https://manualjcalculator.com/wp-content/uploads/2014/01/Sample-Manual-J.pdf” ]DOWNLOAD FULL MANUAL J SAMPLE[/button] [button url=”https://www.manualjcalculator.com/#manual-j-calculation” ]VIEW PRICING[/button][/center]

Are You a Contractor? Click Here…
Are you an Architect or an Engineer?
Click Here…
or Call us now at 1-800-810-3280

0 replies

Leave a Reply

Want to join the discussion?
Feel free to contribute!

Leave a Reply

Your email address will not be published. Required fields are marked *